5-7 ___________________________________________________________________________________________________________
MAXQ7667 User’s Guide
5.2.4 External Interrupt Flag Register (Port 1) (EIF1)
Register Description: External Interrupt Flag Register (Port 1)
Register Name: EIF1
Register Address: Module 00h, Index 04h
Bits 15 to 8: Reserved.
Read returns 0, write ignored.
Bit 7: Interrupt 7 Edge Detect (IE7). This bit is set when a negative edge (IT7 = 1) or a positive edge (IT7 = 0) is detected on the inter-
rupt 7 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 6: Interrupt 6 Edge Detect (IE6). This bit is set when a negative edge (IT6 = 1) or a positive edge (IT6 = 0) is detected on the inter-
rupt 6 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 5: Interrupt 5 Edge Detect (IE5). This bit is set when a negative edge (IT5 = 1) or a positive edge (IT5 = 0) is detected on the inter-
rupt 5 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 4: Interrupt 4 Edge Detect (IE4). This bit is set when a negative edge (IT4 = 1) or a positive edge (IT4 = 0) is detected on the inter-
rupt 4 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 3: Interrupt 3 Edge Detect (IE3). This bit is set when a negative edge (IT3 = 1) or a positive edge (IT3 = 0) is detected on the inter-
rupt 3 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 2: Interrupt 2 Edge Detect (IE2). This bit is set when a negative edge (IT2 = 1) or a positive edge (IT2 = 0) is detected on the inter-
rupt 2 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 1: Interrupt 1 Edge Detect (IE1). This bit is set when a negative edge (IT1 = 1) or a positive edge (IT1 = 0) is detected on the inter-
rupt 1 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
Bit 0: Interrupt 0 Edge Detect (IE0). This bit is set when a negative edge (IT0 = 1) or a positive edge (IT0 = 0) is detected on the inter-
rupt 0 pin. Setting this bit to 1 generates an interrupt to the CPU if enabled. This bit remains set until cleared by software or a reset. It
must be cleared by software before exiting the interrupt source routine or another interrupt will be generated as long as this bit is set.
r = read, w = write
Note: This register is cleared to 00h on all forms of reset.
Bit #
15 14 13 12 11 10 98
Name — — ——————
Reset 0 0 0 0 0 0 0 0
Access r r rrrrrr
Bit #
76543210
Name IE7 IE6 IE5 IE4 IE3 IE2 IE1 IE0
Reset 0 0 0 0 0 0 0 0
Access rw rw rw rw rw rw rw rw