MAXQ7667 User’s Guide
4.1.7 Interrupt Identification Register (IIR)
The first six bits in this register indicate interrupts pending in modules 0 to 5, one bit per module. The eighth bit, IIS, indicates a pend-
ing system interrupt, such as from the watchdog timer. The interrupt pending flags will be set only for enabled interrupt sources wait-
ing for service. The interrupt pending flag will be cleared when the pending interrupt sources within that module are disabled or when
the interrupt flags are cleared by software.
Register Description:
Interrupt Identification Register
Register Name: IIR
Register Address: Module 08h, Index 0Bh
Bit 7: Interrupt Identifier Flag for System Modules (IIS)
Bit 6: Reserved.
Read 0, write ignored.
Bits 5 to 0: Interrupt Identifier Flag for Register Module 5 to 0 (II[5:0])
4.1.8 System Clock Control Register (CKCN)
The 8-bit CKCN register is part of the system register group and used to support system clock generation. It controls the system clock
speed and power management mode selection. See Section 5 for the description of this register.
Register Description:
System Clock Control Register
Register Name: CKCN
Register Address: Module 08h, Index 0Eh
Bit #
7 6543210
Name IIS — II5 II4 II3 II2 II1 II0
Reset 0 0 0 0 0 0 0 0
Access r r r r r r r r
r = read
Note: This register is cleared to 00h on all forms of reset.
Bit #
76543210
Name XTRC — RCMD STOP SWB PMME CD1 CD0
Reset 0 0 0 0 0 0 0 0
Access rw r r rw rw rw rw rw
r = read, w = write
Note: See bit descriptions in Section 15.