Vista de pagina 210
12-13 _________________________________________________________________________________________________________
MAXQ7667 Users Guide
12.3.2.2 Breakpoint Register 4 (BP4)
Register Description: Breakpoint Register 4
Register Name: BP4
This register is accessible only via background mode read/write commands.
When (REGE = 0): This register serves as one of the two data memory address breakpoints. When DME is set in background mode,
the debug engine monitors the data memory address bus activity while the CPU is executing the user program. If an address match
is detected, a break occurs, allowing the debug engine to take over control of the CPU and enter debug mode.
When (REGE = 1): This register serves as one of the two register breakpoints. A break occurs when the destination register address
for the executed instruction matches with the specified module and index. When used as register breakpoint, the bits BP4[3:0] are rec-
ognized as module specifier and bits BP4[8:4] are recognized as the register index within the module. The bits BP4[15:9] are ignored.
This register defaults to FFFFh after a power-on reset or test-logic-reset TAP state.
Bits 15 to 0: Breakpoint Register 4 Bits 15:0 (BP4[15:0])
Bit #
15 14 13 12 11 10 98
Name BP415 BP414 BP413 BP412 BP411 BP410 BP49 BP48
Reset 1 1 1 1 1 1 1 1
Access s s s s s s s s
Bit #
76543210
Name BP47 BP46 BP4 5 BP44 BP43 BP42 BP41 BP40
Reset 1 1 1 1 1 1 1 1
Access s s s s s s s s
s = special (accessible only by background mode read/write commands)