MAXQ Family User’s Guide:
MAXQ2010 Supplement
16-2
• Registers SPIB, I2CBUF, and ADDATA are not read, and their values are returned as 0000h.
The first byte output by this command is the value 144 (090h), which represents the number of peripheral register
words output. Table 16-1 lists the remaining 352 bytes output by this command.
Table 16-1. Output from DebugReadMap Command
x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
0x
PO0 PO1 PO2 PO3 EIF0 EIE0 — —
1x
PI0 PI1 PI2 PI3 EIES0 — — PWCN
2x
PD0 PD1 PD2 PD3 — — — —
3x
RTRM RCNT RTSS RTSH RTSL RSSA RASH RASL
4x
PO4 PO5 PO6 0000h EIF1 EIE1 EIF2 EIE2
5x
PI4 PI5 PI6 EIES1 EIES2 SVM — —
6x
PD4 PD5 PD6 — — SPICN SPICF SPICK
7x
— — — — — — — —
8x
MCNT MA MB MC2 MC1 MC0 LCFG —
9x
MC1R MC0R LCRA LCD0 LCD1 LCD2 LCD3 LCD4
Ax
LCD5 LCD6 LCD7 LCD8 LCD9 LCD10 LCD11 LCD12
Bx
LCD13 LCD14 LCD15 LCD16 LCD17 LCD18 LCD19 LCD20
Cx
0000h I2CST I2CIE — SCON0 SBUF0 SCON1 SBUF1
Dx
SMD0 PR0 SMD1 PR1 I2CCN I2CCK I2CTO I2CSLA
Ex
— — — — — — — —
Fx
— — — — — — — —
10x
TB0R TB0C TB1R TB1C TB2R TB2C ADST ADADDR
11x
TB0CN TB0V TB1CN TB1V TB2CN TB2V ADCN 0000h
12x
AP APC PSF IC IMR SC IIR CKCN WDCN 00 A[0] A[1] A[2]
13x
A[3] A[4] A[5] A[6] A[7] A[8] A[9] A[10]
14x
A[11] A[12] A[13] A[14] A[15] IP SP+1 IV
15x
LC[0] LC[1] OFFS DPC GR BP DP[0] DP[1]