Maxim-integrated 73M1822/73M1922 Control Module Manual de usuario Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
UG_1x22_053 73M1822/73M1922 Control Module User Guide
Rev. 1.0 55
6.8 Loopback Services
6.8.1 M1X22_LOOPBACK
Description
This IOCTL is used for managing the loopback session initiating, clearing or retrieving the status of
current active loopback session on a given channel. Only one loopback session can be active per
channel. For reading the status the loopback “mode” will be returned in the structure
M1X22_LOOPBACK_t pointed to by the “param” field.
#define M1X22_LOOPBACK _IOWR(0xA4, 0xBD, unsigned int)
Prototype
int ioctl (
int chan_fd,
int M1X22_LOOPBACK,
unsigned long param );
Parameters
Data Type Name Description
int
chan_fd
Channel descriptor.
int
M1X22_LOOPBACK
I/O control identifier for this operation.
unsigned long param
Pointer to structure
M1X22_LOOPBACK_t
.
Return Values
Data Type Description
unsigned int
0 – Successful.
-FAULT Failed to perform loopback request.
Vista de pagina 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 85 86

Comentarios a estos manuales

Sin comentarios