Maxim-integrated 73M1822/73M1922 Control Module Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
73M1822/73M1922 Control Module User Guide UG_1x22_053
26 Rev. 1.0
6.1.5 M1X22_PHONE_VOLUME_SET
Description
The gain of both transmit and receive path can be controlled by digital and/or analog means. This IOCTL
provides an easy way to set the transmit and receive gain.
#define M1X22_PHONE_VOLUME_SET _IOWR(0xA4,0xCA,unsigned int)
Prototype
int ioctl (
int chan_fd,
int M1X22_PHONE_VOLUME_SET,
unsigned long param );
Parameters
Data Type Name Description
int
chan_fd
Channel descriptor.
int
M1X22_PHONE_VOLUME_SET
I/O control identifier for this operation.
unsigned long param
Pointer to structure txrx_gain (see Section
7.4).
Return Values
Data Type Description
int
0 – Successful.
(-1) Failed.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 85 86

Comentarios a estos manuales

Sin comentarios