Maxim-integrated 73M1822/73M1922 Control Module Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
UG_1x22_053 73M1822/73M1922 Control Module User Guide
Rev. 1.0 17
5.2.4 M1X22_NOPOH_DETECT
This event is generated when a parallel phone goes on hook.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_NOPOH_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.5 M1X22_POLARITY_CHG
This event is generated when there is a voltage reversal occurs on the line.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_POLARITY_CHG
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
N/A.
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
5.2.6 M1X22_RING_DETECT
This event is generated at the beginning of the ring burst.
Parameters
Data Type Name Description
unsigned int
event_id
M1X22_RING_DETECT
.
unsigned int
channel_id
Channel ID.
unsigned int
event_cnt
Number of events that remain in the queue.
unsigned int
event_data1
Ring burst frequency (in Hz)
unsigned int
event_data2
N/A.
unsigned int
event_data3
N/A.
unsigned int
event_data4
N/A.
Vista de pagina 16