UG_1x22_053 73M1822/73M1922 Control Module User Guide
Rev. 1.0 29
6.2 Events and Status Service
The driver can be queried for a variety of current status of the modem line via IOCTLs. Table 2
summarizes these services.
Table 2: Modem Line Status Services
Events and Status Description Descriptor
Modem line ring status commands. Channel
Modem line polarity status commands. Channel
Modem line battery status command. Channel
Modem line POH status command. Channel
Event retrieval command. Device
Retrieve last error code command. Device/Channel
6.2.1 M1X22_RNG_GET
Description
Gets the current ring status of the modem line. The current ring status is maintained in the driver internal
variable. This variable is being retrieved by use application using this command.
#define M1X22_RNG_GET _IOWR(0xA4,0xB8,unsigned int)
Prototype
int ioctl (
int chan_fd,
int M1X22_RNG_GET,
unsigned long param );
Parameters
Data Type Name Description
Channel descriptor.
I/O control identifier for this operation.
N/A.
Return Values
Data Type Description
The return value can be either of the following:
0 – No ring signal occurred on the modem line.
1 – The modem line is ringing, signaling of incoming call.