MAX15301 PMBus Command Set User’s Guide
Rev 1 Page 37 of 53
MFR_MODEL
Reference:
Standard Command
Lockable:
Yes
Command Code:
0x9A
Format:
ASCII string
Data Bytes:
13
Units:
N/A
Transfer:
Read/Write Block
Factory Value:
Null string
Description/Notes:
See Section 22.2.2 of the PMBus Specification Part II.
Note that the MAX15301 implements MFR_MODEL as a fixed-width string, not as part of a shared
memory space.
MFR_REVISION
Reference:
Standard Command
Lockable:
Yes
Command Code:
0x9B
Format:
ASCII string
Data Bytes:
7
Units:
N/A
Transfer:
Read/Write Block
Factory Value:
Null string
Description/Notes:
See Section 22.2.3 of the PMBus Specification Part II.
Note that the MAX15301 implements MFR_REVISION as a fixed-width string, not as part of a shared
memory space.
MFR_LOCATION
Reference:
Standard Command
Lockable:
Yes
Command Code:
0x9C
Format:
ASCII string
Data Bytes:
8
Units:
N/A
Transfer:
Read/Write Block
Factory Value:
Null string
Description/Notes:
See Section 22.2.4 of the PMBus Specification Part II.
Note that the MAX15301 implements MFR_LOCATION as a fixed-width string, not as part of a shared
memory space.
MFR_DATE
Reference:
Standard Command
Lockable:
Yes
Command Code:
0x9D
Format:
ASCII string
Data Bytes:
6
Units:
N/A
Transfer:
Read/Write Block
Factory Value:
Null string
Description/Notes:
See Section 22.2.5 of the PMBus Specification Part II.
Note that the MAX15301 implements MFR_DATE as a fixed-width string, not as part of a shared
memory space.
The recommended format is YYMMDD where Y, M, and D are integer values from 0 to 9, inclusive.