73M1822/73M1922 Modem API User Guide UG_1x22_055
18 Rev. 1.0
2.20 M1X22_GetVoltageIET
Description
Read the line voltage IET table entry.
Prototype
int M1X22_GetVoltageIET (
M1X22_HANDLE channel,
unsigned int ietIndex,
M1X22_IET_t *pIET );
Parameters
Data Type Name Description
M1X22_HANDLE
channel
Channel handle obtained from open channel.
unsigned int
ietIndex
IET entry index row number (0 9).
M1X22_IET_t
*pIET
Pointer to an output structure M1X22_IET_t.
Return Values
Data Type Description
M1X22_RET
M1X22_SUCCESS Successfully read the IET entry.
M1X22_FAILED Failure.
2.21 M1X22_UpdateVoltageIET
Description
Perform the line voltage IET table update.
Prototype
int M1X22_UpdateVoltageIET (
M1X22_HANDLE channel,
unsigned int ietIndex,
M1X22_IET_t *pIET );
Parameters
Data Type Name Description
M1X22_HANDLE
channel
Channel handle obtained from open channel.
unsigned int
ietIndex
IET entry index row number (0 9).
M1X22_IET_t
*pIET
Pointer to an input structure M1X22_IET_t.
Return Values
Data Type Description
M1X22_RET
M1X22_SUCCESS Successfully update the IET entry.
M1X22_FAILED Failure.