Maxim-integrated 73M1966B Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
UG_1x66B_002 73M1866B/73M1966B GUI User Guide
Rev. 1.1 13
2.2.3 Controls for Registers R13 to R1C
Register Bit Name Summary Description Data Sheet
Section
R13[7:6] DCIVn DC Current Voltage Characteristic Control 10.6
R13[5] ILM Current Limit Enable 0 = no limit, 1 = 42 mA current limit 10.6
R13[4] ACCEN AC Cancellation Enable 10.6
R13[3] PLDM Pulse Dialing Enable 10.6
R13[2] OVDTH Over-Voltage Threshold 11.12
R13[1] IDISPD Discharge and Pulse Dialing 10.6
R13[0]
SEL16K
Sample Rate Mode Configuration Select
8.8
R14[7]
TXBST
Transmit Boost
8.8
R14[6:5] DAAn Data Access Arrangement
Used with TXBST to manage transmit level.
8.8
R14[3] RXBST Received Boost
If set to 1, receive signal is increased by 20 dB.
8.8
R14[2]
RLPNH
Receive Low Pass Notch
0 = Selects Receive Low Pass Notch (RLPN) at 12 kHz.
1 = Selects RLPN at 16 kHz.
10.6
R14[1:0] RXGn Receive Gain Control 8.8
R15[7] ENOLD Enable Over-Load Detector 11.12
R15[6] DISNTR Disable No-Transition Timer 11.12
R15[5]
CHPSEN
Enable Chopper Stabilization
10.6
R15[4]
CIDM
Caller ID Mode
11.12
R15[3] THEN Enable Transhybrid Circuit 10.6
R15[2] ENUVD Enable Under Voltage Detector 11.12
R15[1] ENOVD Enable Over-Voltage Detector 11.12
R15[0] ENOID Enable Over-Current Detector 11.12
R16[7] TXEN Transmit Path Enable 8.8
R16[6] RXEN Receive Path Enable 8.8
R16[5] RLPNEN Receive Low Pass Notch Enable 10.6
R16[4]
ATEN
Active Termination Loop Enable
10.6
R16[3:0]
ACZn
Active Termination Loops
10.6
R17[5] RXOCEN Rx DC Offset Calibrate Enable 8.8
R18[7:4] TESTn Enable Loopback Mode 12.7
R19[7] POLL Polling Enable 6.1